Flowcomputer for continuous flow metering in pipelines

Scheme flow computer
The Pipeline Master accured continuously at the transfer points of pipelines the flow rate. Six counter blocks for the acqusition are available. One non resetable counter integrates all quantities. With the five additional counters batch processes can be counted. A batch can be started and stopped automatically, by pressing a key, by activating a digital input or by setting a Modbus register. This batch can be printed and stored.

Display:

Masse-Anzeige des Flowcomputers The Pipeline Master displays following values:
  • actual mass flow
  • actual volume flow
  • actual standard volume flow
  • Dichteanzeige des Flowcomputers
  • actual temperature
  • actual pressure
  • actual density
  • actual calculated base density
  • Standard-Volumen-Anzeige des Flowcomputers
  • counter blocks A - F
All available forward counters, revers counters, error counters and averages of density, temperature and pressure can be displayed in the several counter blocks.

Printout:

Up to 16 Pipeline Master can be connect to one PCC 400. The printed counters an measuring points can be selected.

Storage:

The printed datas are also stored in the PCC 400 and can be printed again as copy.

API flow conversion:

Through various flow conversions it is possible to calculate the volume flow at base temperature for petroleum products and for biodiesel. The flow input signal can be volume or mass.

Technical Data:

Pipeline Master 110 (i):    IP 65 field housing device
                                    dimensions: 240 mm x 240 mm x 120 mm
Pipeline Master 210 (i):    panel mount, front IP65
                                    dimensions: 144 mm x 144 mm x 120 mm

Inputs and outputs:

  • 1 x double pulse input, active
  • 3 x analog input 4 - 20 mA, passive
  • 5 x digital input, active
  • 5 x digital output, passive
  • 2 x Modbus interface
 